Optifuse IR
Optifuse IR is a light diffusion coating for greenhouses that combines the diffusion of incoming light with efficient protection against heat. It is cleaned off with Topclear Fuse, the Sudlac cleaner designed for that purpose.
Developed for hot areas and sensitive crops, Optifuse IR delivers a very high diffusion rate while keeping light loss to a minimum. It is highly wear resistant and goes onto the outside of any greenhouse type, on glass and plastic roofs alike. That combination supports better photosynthesis together with temperature regulation under cover.
Optifuse IR diffuses the light and cools the greenhouse
Incoming light is diffused and reaches every leaf of the plant, high and low, which improves photosynthesis and transpiration. Humidity and temperature are better regulated, with a better CO2 level inside the greenhouse. Studies have shown that diffuse light combined with a drop in temperature has a beneficial effect on production, quality and crop growth.
Optifuse IR must be diluted with water before it is sprayed onto the greenhouse. For optimal diffusion it is preferably applied by machine, so as to reach an even spread.
diffusion
Depending on the dilution chosen, Optifuse IR diffuses incoming light throughout the greenhouse, for a diffusion rate of 85-90%.
heat reflection
The coating sends part of the infrared radiation back before it heats the greenhouse, with 17-22% NIR reflection.
application methods
Optifuse IR goes on by machine, by hand, by drone or by helicopter, which leaves a choice of 4 methods depending on the equipment available.
Optifuse IR is a milky liquid diffusion coating, supplied in 15 kg buckets. It is designed for outside application on glass and plastic roofs. For professional use only.
Application is preferably done by machine, so as to reach an even spread, and remains possible by hand, by drone or by helicopter. Optifuse IR is diluted with clean water before spraying: 1,000 to 1,500 L of liquid per hectare by machine, 1,700 to 2,000 L by hand. Two reference dilutions, 17 or 22 buckets per hectare for 2,000 L of liquid, give 85% or 90% diffusion and 17% or 22% NIR reflection.
We recommend applying Optifuse IR in the following conditions:
- An outside temperature between 10 and 30 °C
- A wind speed below 2 m/s (7 km/h)
- For fast drying: relative humidity (RH) < 80%
- Do not apply Optifuse IR to a wet surface or when rain is forecast within 6 hours
Optifuse IR is cleaned off with Topclear Fuse, at the moment the grower chooses. Cleaning calls for at least 240 L of Topclear Fuse per hectare, diluted in 1,260 to 1,760 L of water, depending on the application method. Topclear Fuse is applied when substantial rain is forecast within the week, as the rain washes the coating away. It goes neither onto a wet surface nor during rain.
Complete the light diffusion
Eclipse LD
Long-lasting coating against heat and light, suitable for every type of greenhouse.
Eclipse LD²
Long-lasting coating against heat and light, designed for sensitive crops.
Optifuse
Long-lasting coating that diffuses light, with maximum light transmission to the crop.
Transpar
Long-lasting coating against heat, letting more grow-light into the greenhouse.
Topclear
Cleaner for long-lasting shading and diffusion coatings, to be used at the moment of your choice.
WHY SUDLAC
The greenhouse shading specialist since 1959
At Sudlac, we have been developing quality greenhouse shading coatings for more than 65 years, protecting crops by optimising the incoming natural light. Our products help growers protect their crops and their greenhouses from excess light and heat, in order to optimise their production.
Sudlac is recognised worldwide for its reliability and the quality of its coatings. Innovation and sustainability sit at the heart of the brand and keep widening the range of solutions for real-world situations. More than 70% of our distributors have been working with us for 10 years or more.
Our teams are there to adapt the coatings to each individual situation. That close-to-the-field support is what allows us to advise you better every time.
Frequently asked questions
Optifuse IR is a diffusion coating for greenhouses that combines a very high diffusion rate with the reflection of infrared radiation. It was developed for hot areas and sensitive crops, on glass and plastic roofs alike. The grower adjusts the dilution and the application method, then cleans the coating off with Topclear Fuse whenever needed.
Diffused light reaches every leaf of the plant, high and low, while part of the infrared radiation is sent back. Studies have shown that diffuse light combined with a drop in temperature has a beneficial effect on production, quality and crop growth.
With 17 buckets per hectare, Optifuse IR reaches 85% diffusion, 89% PAR light transmission and 17% NIR reflection. With 22 buckets, diffusion rises to 90% and NIR reflection to 22%, for a PAR transmission of 86%.
Optifuse IR goes onto the outside of any greenhouse type, on glass and plastic roofs alike. It is meant for hot areas, while Optifuse is designed for regions with a moderate temperature.
Application is done by machine, by hand, by drone or by helicopter, on a clean and dry roof. The machine is preferred, as it gives a more even spread and limits product loss.
Optifuse IR is cleaned off with Topclear Fuse, at the moment the grower chooses. Cleaning calls for at least 240 L of Topclear Fuse per hectare, diluted in 1,260 to 1,760 L of water, depending on the application method. Topclear Fuse is applied when substantial rain is forecast within the week, on a dry roof.
News & Documentation
Looking for technical documentation or application advice for Optifuse IR? It is all gathered here.
CONTACT US
The right diffusion at the right time
Sudlac specialists advise on product choice, dilution and application, based on the greenhouse type, the crop and the climate. That conversation is best had before the first spray.